Commercial energy compliance and HVAC load calcs, quoted per project.
For Florida commercial buildings we prepare the energy code compliance documents and the HVAC heating and cooling load calculations a permit needs, with engineering by Designda Inc. under its Florida engineering license 39202. Commercial work is quote-only: send the plans, and we come back with a price and a delivery date for that project.
What we prepare
Commercial energy compliance for the Florida Building Code, Energy Conservation, using software the Florida Building Commission has approved for the commercial code. EnergyGauge Summit is approved for the Florida code's own commercial methods and for ASHRAE 90.1-2019 methods 1 2; COMcheck-Web is approved for the ASHRAE 90.1-2019 envelope trade-off and prescriptive paths 3. More in COMcheck vs Florida's commercial compliance options.
Commercial HVAC heating and cooling load calculations. The commercial energy code references ANSI/ASHRAE/ACCA Standard 183 and ACCA Manual N for load calculations under section C403.2.1 4. More in commercial HVAC load calculations in Florida.
Signed and sealed documents where the project needs them, issued by Designda Inc. as the engineering firm.
Why commercial work usually needs a seal
Florida law requires engineering work to be done by a licensed engineer unless an exemption in section 471.003 applies 5 6. The exemption for air-conditioning and mechanical contractors is narrow: it covers projects with an air-conditioning system value of $125,000 or less and, among other limits, HVAC of no more than 15 tons per system or a project designed for 100 or fewer people 5. Commercial projects outside that exemption need engineered, sealed mechanical documents, which is why commercial pricing includes engineering.
Single-family homes are different, and a stamp is normally not required there. See sealed vs unsealed energy calcs and our residential prices.
What to send for a quote
- The full plan set (architectural, plus mechanical and electrical sheets if drawn)
- Building use and occupancy group
- Conditioned square footage and number of stories
- Project address and county
- The mechanical schedule, if you have one
- Owner and/or contractor name, email and phone
- When you need it
Price and turnaround
Commercial projects take longer than our residential calcs and are priced per project, based on the building, the compliance path and the documents needed. The 2–3 business day residential delivery and the residential prices do not apply. Your quote states the price and the delivery date before any work starts, and nothing is charged online.
Sources
- 01Florida Building Commission Energy TAC minutes, July 25, 2023 (EnergyGauge Summit 8.0 approval for the 8th Edition commercial code)floridabuilding.org
- 02Florida Building Commission Energy TAC minutes, Sept 8, 2025 (EnergyGauge Summit 9.00 approval)floridabuilding.org
- 03Florida Building Commission Energy TAC minutes, Aug 11, 2023 (COMcheck-Web approval, ASHRAE 90.1-2019 methods)floridabuilding.org
- 042023 Florida Building Code, Energy Conservation (8th Ed.), Chapter 6 [CE] Referenced Standards (ASHRAE/ACCA 183, ACCA Manual N, C403.2.1)up.codes
- 05Florida Statutes 471.003 (2026), Qualifications for practice; exemptionsflsenate.gov
- 06Florida Board of Professional Engineers, "Engineering by Any Other Name Is Still Engineering"fbpe.org