Home/Form R405

Form R405 energy calcs, prepared for Florida permits.

Form R405 is the Florida energy code’s performance-method report. Commission-approved software models the house and compares it with a code-built reference home; under the 8th Edition (2023) it passes when the normalized annual loads come in at 95% of the reference or less, an e-Ratio of 0.95, tightening to 0.85 under the 9th Edition, scheduled for December 31, 2026. We prepare it from $175.

Updated Primary sources · 10 citedReviewed by Designda Inc. · Florida engineering license 39202 · verify
Form R405 at a glance
8th Ed. (2023)9th Ed. (2026)
Pass at e-Ratio≤ 0.95≤ 0.85
Window SHGC cap0.500.40
Duct-test exceptionAvailableRemoved
Full table ↓
At a glance
Form
Form R405, performance methodCommission-approved software2
Passes at
e-Ratio ≤ 0.95≤ 0.85 under the 9th Ed. (2026), scheduled Dec 31, 20264
Code edition
FBC Energy Conservation, 8th Ed. (2023)9th Ed. (2026) scheduled for Dec 31, 2026 · what changes
Evidence
10 primary sourcesCode sections, the state checklist and county rules · references
Price
$175 · $225 · $400Energy calcs · Manual J · both (stamp +$300). Same in all 67 counties · price list
Ready by
2–3 business daysExpedited: within 24 business hours. +$150 surcharge. Clock starts when complete plans pass intake (3:00 PM ET cutoff) · how it works

What Form R405 is

Florida’s residential energy code gives three ways to comply: the prescriptive Sections R401 through R404, the performance path in Section R405 plus every provision marked mandatory, or the energy rating index in R406.1 For houses of three stories or fewer, the performance route is documented on Form R405, which must come from software the Florida Building Commission has approved.2

The software builds two houses: yours, from the plans, and a standard reference design that meets the code baseline. EnergyGauge reports the comparison as the e-Ratio, normalized annual loads of the proposed house over the reference; today it must be 0.95 or less.16 Because the comparison is whole-house, a large west-facing slider can be paid for with a better air handler location, tighter ducts or a higher-efficiency system, which the prescriptive Form R402 does not allow. Our R405 vs R402 guide walks through when each path makes sense.

What goes in with the permit

6 items at permit · 3 more before the certificate of occupancy

The state’s documentation checklist for the 2026 performance method lists what an R405 application includes.3

Form R405-2026 documentation checklist3
ItemWhen
This checklistPermit application
Form R405-2026 reportPermit application
Input summary checklist for field verification (usually four pages)Permit application
Energy Performance Level (EPL) display cardPermit application
HVAC sizing and selection per ACCA Manual S, or the R403.7 exceptionsPermit application
Mandatory requirements (five pages)Permit application
Air barrier and insulation inspection checklist, Table R402.4.1.1Before the certificate of occupancy
Envelope leakage test reportBefore the certificate of occupancy
Duct leakage test report, when the R405 claims anything other than default leakageBefore the certificate of occupancy

The EPL display card is more than a permit form: the checklist quotes Florida law requiring it as an addendum to each sales contract for new homes, presold or not, and the building official checks that it matches the plans before final approval.3 We deliver the R405 report, input summary and EPL card as separate PDFs so they drop into the right upload slots. Seminole County, for one, asks for energy calcs in the ePlan documents folder under a plain name such as “Energy Calculations” or “Ecalcs.”8

What reviewers check

Signatures, a PASS line, the right edition, and a county cover-sheet rule

The example report published with the state checklist shows the page a plan reviewer reads first: the project and permit office, the envelope and equipment inputs, total proposed modified loads against total baseline loads, a PASS result, and signature lines for the preparer, the owner or agent, and the building official.3 The same example notes the conditions compliance depends on, such as an envelope leakage test no greater than 7.0 ACH50 and a certified factory-sealed air handler where the model assumes one.3

Counties add their own rules on top. Unincorporated Lee County wants Form R405 uploaded as the energy-calculation cover sheet, signed and showing a passing result.7 Seminole lists “provide energy calculations” among its common residential review comments.8 In our experience the fixes are mostly paperwork: an unsigned page, a report merged into the plan set, or inputs that no longer match a revised window schedule. Our guide to why energy calcs get rejected covers each one.

8th vs 9th Edition

e-Ratio 0.95 → 0.85 · window SHGC cap 0.50 → 0.40 · duct-test exception removed
What changes on the performance path45
8th Ed. (2023)9th Ed. (2026)
R405 e-Ratio to pass0.950.85
Max area-weighted window SHGC0.500.40
R405 duct-testing exceptionAvailableRemoved

The 9th Edition is scheduled to take effect December 31, 2026, and it tightens the performance target to an e-Ratio of 0.85, lowers the window SHGC ceiling and removes the R405 duct-testing exception.45 The adopting rule, 61G20-1.001, was published as a proposed rule on September 23, 2026, so the date can still move.10 Which edition governs your house is set by law: the code in effect on the date you apply for the permit applies for the life of that permit.9 A design that passes at 0.93 this year can fail at 0.85 next year without any change to the plans. See what changes in the 2026 code.

What we need from you

Plans, window schedule, address and your expected application date

An R405 is only as good as its inputs, so intake asks for what the model actually reads:

  • Floor plan with dimensions and the elevations or wall sections, so wall, ceiling and floor areas and insulation are right.
  • Window and door schedule with U-factor and SHGC for each unit. This is the input that most often decides pass or fail in Florida.
  • Mechanical plan if you have one, or the planned equipment and air handler location.
  • Project address and county, which set the climate zone and the building department’s checklist.
  • Expected permit application date, which sets the code edition.

The 2–3 business-day clock starts when that checklist passes. Upload on the order page, or see how ordering works.

Form R405 questions

3 answers · What is Form R405 in Florida?

What is Form R405 in Florida?

Form R405 is the compliance report for the performance path of the Florida Building Code, Energy Conservation. Commission-approved software compares the proposed house with a standard reference design; the house passes when its normalized heating, cooling and water-heating loads are at most 95% of the reference (e-Ratio 0.95) under the 8th Edition, and every mandatory provision is met.

Does a Form R405 submittal need a Manual J?

The state’s R405-2026 checklist lists HVAC system sizing and selection based on ACCA Manual S, or the exceptions in Section R403.7, as part of the package. Manual S selects equipment against loads from Manual J or another approved method, so in practice the load calculation travels with the R405.

Which R405 edition applies if I apply for the permit in January 2027?

Florida law ties a permit to the code edition in effect on the date of application. If the 9th Edition takes effect on December 31, 2026 as scheduled, a January 2027 application is checked against the 2026 code, which means the R405-2026 form and the 0.85 e-Ratio. Tell us the date you expect to apply and we prepare the calc to that edition.

Price

$175Energy calcs (R405)
$400R405 + Manual J
+$300PE stamp, any package
2–3Business days

One statewide price in all 67 counties. Building departments decide what they accept; we don’t guarantee approval. Revisions for plan-review comments on the same design are free.

Start your order Plans in, price shown before you pay

Sources

10 primary references · numbered to match the citations
  1. 012023 Florida Building Code, Energy Conservation (8th Ed.), Chapter 4 [RE]: R401–R406up.codes
  2. 022023 Florida Building Code, Energy Conservation (8th Ed.), Chapter 1 [RE]: R101.5, R103 compliance forms and certificationup.codes
  3. 03Florida DBPR, Form R405-2026 Residential Energy Conservation Code Documentation Checklist with example report (Florida Building Commission, Energy TAC)floridabuilding.org
  4. 04Florida Building Commission, Analysis of Changes for the 9th Edition (2026) Florida Codes, Energy (Residential): R405.3floridabuilding.org
  5. 05DBPR, Significant Provision Changes, 9th Edition (2026) FBC-Energy Conservationfloridabuilding.org
  6. 06FSEC-CR-2128-25 for DBPR, 2024 IECC vs 2023 FBC-EC residential code review (Florida Building Commission, Energy TAC)floridabuilding.org
  7. 07Lee County, Digital Projects FAQ (Form R405 cover sheet)leegov.com
  8. 08Seminole County, Building Divisionseminolecountyfl.gov
  9. 09Florida Statutes 553.73(7)(d)flsenate.gov
  10. 10Florida Administrative Register, Notice 31378159 (Rule 61G20-1.001)flrules.org