Home/Guides/Manual J for A/C replacement

Manual J for A/C replacement: what Florida asks for on a changeout.

The sizing rule in Florida’s codes, R403.7.1 in the energy code and M1401.3 in the residential code, says equipment is sized with ACCA Manual S on Manual J loads, with no carve-out for replacements, and state law says replacement systems should be installed with an equipment sizing analysis. What your building department asks to see on a changeout permit varies: some want the Manual J and S, others only the AHRI certificate.

Updated Primary sources · 10 citedReviewed by Designda Inc. · Florida engineering license 39202 · verify
Changeout paperwork
Like-for-likeDuct work changed
Alachua CountyAHRI + Manual J & SAdds Manual J & D
Port St. LucieChangeout formFull mechanical permit
Pasco CountyAHRI certificateSee county form
Full table ↓
At a glance
Code basis
FBC 8th Ed. (2023)R403.7.1 and M1401.312
State law
F.S. 553.912Sizing analysis and duct inspection for replacements3
Code edition
FBC Energy Conservation, 8th Ed. (2023)9th Ed. (2026) scheduled for Dec 31, 2026 · what changes
Evidence
10 primary sourcesCode, statute and department forms · references
Price
$175 · $225 · $400Energy calcs · Manual J · both (stamp +$300). Same in all 67 counties · price list
Ready by
2–3 business daysExpedited: within 24 business hours. +$150 surcharge. Clock starts when complete plans pass intake (3:00 PM ET cutoff) · how it works

What the code says

Florida’s energy code requires heating and cooling equipment to be sized in accordance with ACCA Manual S, based on loads calculated with ACCA Manual J or another approved method, for the building’s actual orientation. It rules out designer safety factors and allowances for future expansion, and its last sentence speaks of “new or replacement” equipment meeting federal minimum efficiency.1 The residential code’s M1401.3 states the same Manual S on Manual J rule.2

M1401.3 gives two exceptions to the Manual S capacity limit: multistage or variable-refrigerant-flow equipment whose published range covers the calculated loads, and the case where no manufacturer size meets both the sensible and total load, which allows the next larger standard size.2 Cooling capacity is otherwise capped at 1.15 times the calculated total load, as our Manual J, S & D guide explains.1

What state law adds

F.S. 553.912 · sizing analysis and duct inspection for replacements

Section 553.912 of the Florida Statutes requires every air conditioner sold or installed in the state to meet the energy code’s minimum efficiency, and states the Legislature’s intent that replacement residential systems be installed with quality installation procedures, “including, but not limited to, equipment sizing analysis and duct inspection.”3 The same section says existing equipment need not be brought up to the current minimums, sizing or duct sealing.3 Read together: what you leave alone is grandfathered, and what you install new is expected to be sized.

What departments ask for

4 departments · from AHRI only to Manual J, S and D

Here is how four Florida building departments handle a residential changeout, from their own published forms.

DepartmentChangeout submittalSource
Alachua CountyAHRI certificate plus ACCA Manual S and Manual J, as required by FBC M1401.3; a scope-of-work document noting any duct replacement4
Pasco CountyAHRI certificate for a change-out; Manual J and Manual S data for a new installation7
City of Port St. LucieChangeout form covers like-for-like equipment with no duct alterations; load calculations required to replace a mini-split6
Seminole CountyA permit is required to replace a condenser, an air handler or both, or a package unit8

If your county isn’t listed, its changeout form or permit checklist is the place to look. Our county pages, such as Seminole and Volusia, link each department’s official page.

When a changeout becomes a design job

Duct work, mini-splits and added space change the paperwork

Touching the ducts is the usual trigger. Alachua County’s replacement checklist adds Manual J and Manual D forms, and a rough-in mechanical inspection, when ductwork is replaced, altered or added.5 Port St. Lucie sends work with new ductwork to a full mechanical permit, and when 50% or more of the duct system is replaced it wants a separate permit with an AHRI certificate and a layout.6 A new mini-split there needs the AHRI certificate, energy compliance forms, a heating and cooling calculation and a placement sketch.6

Adding conditioned space is a different job again: an addition brings the energy code’s compliance forms with it. For that, start with Form R405 vs R402.

Why size the replacement

The old unit’s tonnage is not a load calculation

In our experience, the existing nameplate is the least reliable number in the house. Many Florida homes have had new windows, attic insulation or a closed-in porch since the original unit went in, and each changes the load. An oversized system short-cycles, and in a warm-humid climate that leaves moisture in the air; every Florida county is in a humid climate zone, which is why the latent part of the load matters as much as the tons.10 Design conditions are set per county, from 86°F to 94°F at the 1% cooling level, so the same house carries a different load in Gulf County than in Duval.9

For a replacement we need the conditioned area, window types, insulation you know of, the orientation, and a photo of the existing equipment data plates. Our Energy + Manual J package covers the Manual J and a target tonnage range at one statewide price (Manual S and D come later, once the equipment is chosen); see the price list.

Questions

3 answers · Does Florida require a Manual J for an A/C replacement?

Does Florida require a Manual J for an A/C replacement?

The sizing sections of the energy and residential codes require equipment sized per Manual S on Manual J or another approved load method, and Florida law states the intent that replacement systems be installed with an equipment sizing analysis. Whether the load calc is submitted with a changeout permit depends on the county or city: Alachua County asks for Manual J and S, while Pasco asks only for the AHRI certificate.

Can I replace my A/C with the same size unit without a load calc?

Many departments process a like-for-like changeout without plan review. Port St. Lucie’s changeout form, for example, covers replacement with like-for-like equipment and no duct alterations. The code’s sizing rule still applies to what you install, and the old unit’s tonnage is not a load calculation; oversized equipment is common in older Florida homes.

Do I need a permit to replace an A/C condenser in Florida?

Generally yes. Seminole County, for example, lists replacement of a condenser, an air handler or both, or a package unit, as work that requires a permit. Check your building department’s changeout form for what it wants attached.

Price

$175Energy calcs (R405)
$400R405 + Manual J
+$300PE stamp, any package
2–3Business days

One statewide price in all 67 counties. Building departments decide what they accept; we don’t guarantee approval. Revisions for plan-review comments on the same design are free.

Start your order Plans in, price shown before you pay

Sources

10 primary references · numbered to match the citations
  1. 012023 Florida Building Code, Energy Conservation (8th Ed.), Chapter 4 [RE]: R401–R406up.codes
  2. 022023 Florida Building Code, Residential (8th Ed.), Chapter 14: M1401.3 Equipment and appliance sizingup.codes
  3. 03Florida Statutes 553.912, Air conditionersflsenate.gov
  4. 04Alachua County Growth Management, HVAC Change Out, Residential: required submittal documents (PDF, June 2025)growth-management.alachuacounty.us
  5. 05Alachua County Growth Management, HVAC Replacement, Residential: inspection checklist (PDF, Feb 2026)growth-management.alachuacounty.us
  6. 06City of Port St. Lucie Building Department, A/C Changeout Permit Application (PDF, Jan 2026)cityofpsl.com
  7. 07Pasco County, Permit Submittal Requirements: Residential Air Conditioning Units (PDF)cms1files.revize.com
  8. 08Seminole County, Building Divisionseminolecountyfl.gov
  9. 09RESNET / ENERGY STAR, Appendix A: HVAC Design Temperature Limits by State and County (v4, 2019). 1% cooling and 99% heating values drawn from the ASHRAE 2013 Handbook of Fundamentals and ACCA Manual J 8th Ed.resnet.us
  10. 102023 Florida Building Code, Energy Conservation (8th Ed.), Table R301.1, climate zones by countyup.codes